5 Must-Have Features in a Static Var Compensators

Static VAR compensator - Wikipedia

Alternatively Static VAr Generator

In Electrical Engineering, a static VAR compensator (SVC) is a set of electrical devices for providing fast-acting reactive power on high-voltage electricity transmission networks.[1][2] SVCs are part of the flexible AC transmission system[3][4] device family, regulating voltage, power factor, harmonics and stabilizing the system. A static VAR compensator has no significant moving parts (other than internal switchgear). Prior to the invention of the SVC, power factor compensation was the preserve of large rotating machines such as synchronous condensers or switched capacitor banks.[5]

For more information, please visit our website.

The SVC is an automated impedance matching device, designed to bring the system closer to unity power factor. SVCs are used in two main situations:

  • Connected to the power system, to regulate the transmission voltage ("transmission SVC")
  • Connected near large industrial loads, to improve power quality ("industrial SVC")

In transmission applications, the SVC is used to regulate the grid voltage. If the power system's reactive load is capacitive (leading), the SVC will use thyristor controlled reactors to consume VARs from the system, lowering the system voltage. Under inductive (lagging) conditions, the capacitor banks are automatically switched in, thus providing a higher system voltage. By connecting the thyristor-controlled reactor, which is continuously variable, along with a capacitor bank step, the net result is continuously variable leading or lagging power.

In industrial applications, SVCs are typically placed near high and rapidly varying loads, such as arc furnaces, where they can smooth flicker voltage.[1][6]

Description

[edit]

Principle

[edit]

Typically, an SVC comprises one or more banks of fixed or switched shunt capacitors or reactors, of which at least one bank is switched by thyristors. Elements which may be used to make an SVC typically include:

  • Thyristor-controlled reactor (TCR), where the reactor may be air- or iron-cored
  • Thyristor-switched capacitor (TSC)
  • Harmonic filter(s)
  • Mechanically switched capacitors or reactors (switched by a circuit breaker)

By means of phase angle modulation switched by the thyristors, the reactor may be variably switched into the circuit and so provide a continuously variable VAR injection (or absorption) to the electrical network.[2] In this configuration, coarse voltage control is provided by the capacitors; the thyristor-controlled reactor is to provide smooth control. Smoother control and more flexibility can be provided with thyristor-controlled capacitor switching.[7]

The thyristors are electronically controlled. Thyristors, like all semiconductors, generate heat and deionized water is commonly used to cool them.[5] Chopping reactive load into the circuit in this manner injects undesirable odd-order harmonics and so banks of high-power filters are usually provided to smooth the waveform. Since the filters themselves are capacitive, they also export MVARs to the power system.

More complex arrangements are practical where precise voltage regulation is required. Voltage regulation is provided by means of a closed-loop controller.[7] Remote supervisory control and manual adjustment of the voltage set-point are also common.

Connection

[edit]

Generally, static VAR compensation is not done at line voltage; a bank of transformers steps the transmission voltage (for example, 230 kV) down to a much lower level (for example, 9.0 kV).[5] This reduces the size and number of components needed in the SVC, although the conductors must be very large to handle the high currents associated with the lower voltage. In some static VAR compensators for industrial applications such as electric arc furnaces, where there may be an existing medium-voltage busbar present (for example at 33 kV or 34.5 kV), the static VAR compensator may be directly connected in order to save the cost of the transformer.

Another common connection point for SVC is on the delta tertiary winding of Y-connected auto-transformers used to connect one transmission voltage to another voltage.

The dynamic nature of the SVC lies in the use of thyristors connected in series and inverse-parallel, forming "thyristor valves". The disc-shaped semiconductors, usually several inches in diameter, are usually located indoors in a "valve house".

Advantages

[edit]

The main advantage of SVCs over simple mechanically switched compensation schemes is their near-instantaneous response to changes in the system voltage.[7] For this reason they are often operated at close to their zero-point in order to maximize the reactive power correction they can rapidly provide when required.

They are, in general, cheaper, higher-capacity, faster and more reliable than dynamic compensation schemes such as synchronous condensers.[7] However, static VAR compensators are more expensive than mechanically switched capacitors, so many system operators use a combination of the two technologies (sometimes in the same installation), using the static VAR compensator to provide support for fast changes and the mechanically switched capacitors to provide steady-state VARs.

See also

[edit]

Similar devices include the static synchronous compensator (STATCOM) and unified power flow controller (UPFC).

References

[edit]

What is a Static VAR Compensator? - ForumElectrical.com

A static VAR compensator consists of a controlled reactor & a fixed shunt capacitor connected in parallel. 

The reactor is controlled by the SVC's thyristor switch assembly. 

The firing angle of thyristor determines the voltage along the inductor and, as a result, the current flowing through it. 

This allows you to control the inductor's reactive power demand.

This is a parallelly connected static form of VAR absorber or generator whose output is adjusted to replace inductive (or) capacitive current, thereby regulating or managing associated current factors, primarily the bus voltage factor. 

A static VAR compensator depends on thyristors that lack gate switching capability. 

Thyristor functionality and features grasp the SVC changeable reactive impedance. 

This device includes two critical pieces of equipment: TCR and TSR, which are thyristor-controlled capacitors and reactors.

In case of high-voltage electrical transmission lines, the device provides quick reactive power. SVCs are classified as dynamic 

AC transmission networks with voltage regulation and system stability. 

The fundamental static VAR compensator circuit schematic is illustrated below:

The device's thyristor switch assembly governs the reactor, while the firing angle regulates the voltage & current values that pass through the inductor. This allows the inductor's reactive power to be controlled.

This technology has the capacity to eliminate reactive power regulation even over long distances while maintaining zero-time delays. It improves system stability and power factor. 

Some of the schemes used by SVC devices include:

  • Thyristor-regulated capacitor
  • Thyristor-regulated reactor
  • Self-reactor
  • Thyristor-regulated reactor with a constant capacitor
  • Thyristor-regulated capacitor and reactor

In the single-line diagram of the SVC, the reactor may be a shifter internal to the circuit via PAM modulation by the thyristors, resulting in a constantly variable type of VAR to electrical system. In this mode, capacitors govern extended voltage levels, which is well recognized for supplying efficient control. 

As a result, the TCR mode gives better control and reliability. Thyristors can also be electronically regulated.

Thyristors, like semiconductors, deliver heat and utilize deionized water to cool them down. When reactive load is sliced into the circuit, it introduces undesired harmonics, and a wide range of filters are typically utilized to smooth out the wave. 

Because the filters have capacitive operation, they will transfer MVAR to power circuit. 

The structure of the block diagram is illustrated as follows:

The device comes with a control system that includes:

  • A distribution section identifies the thyristor switched capacitors & reactors that need to be switched internally and externally, and calculates the firing angle.
  • A synchronization section includes a phase-locked loop that is synchronized on the pulse generator & the secondary level of voltages, where they send a needed number of pulses to the thyristors.
  • A calculating portion determines the positive '+' voltage that needs to be regulated.
  • A voltage control system that measures the difference between calculated & reference voltage levels.

A phasor simulation technique that is carried out using a powerful section is required to be utilized in order to operate the SVC equipment. It can also be used in 3-phase power networks with synchronous generators, dynamic loads for the execution, and the device's electromechanical variations.

If you want to learn more, please visit our website Tongdian.

Additional reading:
7 Top Single Cell Batteries Manufacturers You Need to Know

High-end static VAR compensators may also be built for accurate voltage regulation. A closed-loop controller allows you to control the voltage. 

It is the static VAR compensator configuration.

Static VAR Compensator function in electronic power supply systems is 

  • To improve the grid's power factor, 
  • Reduce losses in power transformers and transmission lines,
  • Increase power supply efficiency, and 
  • Improve the power supply environment.

As a result, reactive power compensation devices are vital and essential components in power supply systems. A rational selection of compensating devices can reduce network losses & improve grid quality. In contrast, inappropriate selection or use may result in issues such as voltage swings and higher harmonics in the power supply system.

A Static VAR Compensator (SVC) is normally made up of various components, such as a 

  • Thyristor-Controlled Reactor (TCR), 
  • Thyristor-Switched Capacitor (TSC), 
  • Filters, 
  • Control System, and 
  • Auxiliary Components.

A TCR is a reactor that runs in parallel with a power transmission line. It is governed by a thyristor device that controls the inductive reactive power.

The TSC is a capacitor that is linked in parallel to the power transmission line. Thyristor devices regulate the capacitive reactive power.

Filters and reactors utilized to remove harmonics in the power system.

The SVC's control system is in charge of monitoring the voltage & current in the power transmission line, as well as controlling the TCR and TSC to maintain the desired voltage and power factor. 

The control system typically incorporates a microprocessor-based controller that collects sensor signals and delivers them to thyristor devices to modify reactive power injection (or) absorption.

To assure the system's correct functioning and protection, the SVC may also incorporate auxiliary components such as filters, transformers, & protective devices.

An SVC is an electrical device that regulates voltage and reactive power (VAR) in electric power transmission and distribution systems. 

It is a static compensator which utilizes power electronics to regulate the voltage & VAR on the electrical grid.

The SVC consists of two components: 

  • A Thyristor-Controlled Reactor (TCR) & 
  • A Thyristor-Switched Capacitor. 

The TCR & TSC are linked in parallel to the electricity transmission line. The TCR controls inductive reactive power, while the TSC controls capacitive reactive power. 

The combination of the TCR & TSC enables the SVC to inject (or) absorb reactive power rapidly and accurately in order to maintain the target voltage level and increase the system's power factor.

The SVC continually monitors the voltage & current in the power transmission line & changes the reactive power injection or absorption according to the voltage level. 

If the voltage falls below the desired level, the SVC injects reactive power into the system. In contrast, if the voltage goes over the acceptable level, the SVC will take reactive power from the system.

The TCR and TSC are normally connected in series to a common DC bus that is monitored by the control system. 

The control system changes the firing angle of the thyristor devices to control reactive power injection (or) absorption by the TCR & TSC. 

The combination of the TCR & TSC enables the SVC to inject (or) absorb reactive power rapidly and accurately in order to maintain the target voltage level and increase the system's power factor.

The SVC contributes to system stability and improves power factor by injecting (or) absorbing reactive power as needed. This 

  • Reduces system losses and 
  • Improves overall system efficiency.

In general, SVC devices cannot work at line voltage levels; hence, certain transformers must be utilized to step down transmission voltage levels. 

This reduces the equipment and device size required for the compensator, despite considering that wires are required to control the extended levels of the current associated with the minimum voltage.

In contrast, a few static VAR compensators utilized in commercial applications, such as electric furnaces, may contain a dominant mid-range of bus bars. 

To save on transformer costs, a SVC will be connected directly. The other general point of connection in this compensator is the delta tertiary winding of the Y-type autotransformers, which are used to connect transmission voltages to various types of voltage.

The compensator's dynamic behaviour will be similar to that of thyristors, which are coupled in series. The disc type of SCs have a wide range of sizes and are typically installed in valve houses.

A SVC might be operated in two ways:

  • As a voltage-controlling mode that regulates voltage within the threshold values.
  • As VAR regulation mode, which indicates that the device's susceptibility value is kept constant.

The VI characteristics for the voltage controlling mode are as follows:

As long as the susceptance value remains constant within the lower and upper threshold limits imposed by the total reactive power of capacitors & reactors, the voltage value is regulated at the equilibrium point, known as a reference voltage.

When there is significant reactive power at output, voltage decreases occur, with values ranging from 1 to 4%. 

The VI characteristic & equations regarding this condition are presented below:

V = Vref + Xs.I (When the susceptance is between the high & low ranges of capacitor & reactor banks.)

V = ' (I / Bcmax) for condition (B implies that Bcmax)

V = (I / Bcmax) for condition (B implies that BImax)

Are you interested in learning more about Static Var Compensators? Contact us today to secure an expert consultation!

  • These SVC devices can improve the power transmission capacity of transmission lines.
  • The installation of SVCs can help improve the system's transient strength.
  • SVC is commonly used for managing steady states and a wide range of voltages, which is one of its primary advantages.
  • SVC boosts the load power rating, which reduces line losses and improves system efficiency.
  • Controls both continuous and transitory overvoltage.
  • There are no moving parts, therefore less maintenance is required.
  • Additional equipment is required to implement surge impedance compensation since the equipment lacks revolutionary parts.
  • The device is large and heavy.
  • Deliberate dynamic response.
  • The device is not suited for the regulation of voltage up & down due to furnace loads.